HB Series · Product gallery
AC CHARGING + BACKUP · 400–2400 W
HB Series
Compact Backup Inverter
A compact route from battery storage to everyday AC power. HB combines a pure sine wave inverter, AC charger and front-panel status display in a carry-handle enclosure, with eight models for 12, 24 and 48 V systems.
Pure sine wave · Built-in AC charger · 110 / 220 V options
Select a model to see its ratings below.
A COMPACT BACKUP SYSTEM
Choose the battery voltage.
Match the everyday load.
Keep inverter power and storage capacity separate: HB provides the AC conversion and charging, while an external battery bank provides your energy reserve.
12 V
400 / 640 / 800 / 1200 W
HB0512 · HB0812 · HB1012 · HB1512
24 V
1200 / 1600 / 2400 W
HB1524 · HB2024F · HB3024F
48 V
2400 W
HB3048F
SYSTEM OVERVIEW
Where the power goes
Charge an external battery from AC supply. When the system draws on the battery, HB converts stored energy into AC power for your loads.
HB SERIES
Store energy for later. Charge your battery when power is available, then draw on it during battery-powered operation.
Choose your power and storage. Match HB output to your load; choose external battery capacity for the runtime you need.
HB Series · Front controls and carry handle
CHARGING + CONTROL
The everyday controls,
within reach.
01
Recharge from AC power
Built-in AC charging ranges from 8 to 30 A across the models. Set the charge current to suit the external battery.
02
Check the system in one place
See AC voltage and frequency, output frequency, battery voltage and load current on the front display.
03
Plan the space before installation
400–1200 W models: 300 × 144 × 213 mm. The 1600–2400 W models use the larger 385 × 190 × 382 mm enclosure.
THE DETAILS, SIDE BY SIDE
Technical specifications
Compare 8 models by rated output, battery voltage and charging capacity.
Scroll sideways to compare all models.
| Specification | HB0512 | HB0812 | HB1012 | HB1512 | HB1524 | HB2024F | HB3024F | HB3048F |
|---|---|---|---|---|---|---|---|---|
| Output | ||||||||
| Rated output power | 400 W | 640 W | 800 W | 1200 W | 1200 W | 1600 W | 2400 W | 2400 W |
| Battery-mode output voltage | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) | 220 V AC ±10% / 110 V AC ±10% (by configuration) |
| Battery-mode output frequency | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% | 50 / 60 Hz ±1% |
| Output waveform | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave | Pure sine wave |
| AC-mode output voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage | Same as AC input voltage |
| AC-mode output frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency | Same as AC input frequency |
| Transfer time | ≤10 ms | ≤10 ms | ≤10 ms | ≤10 ms | ≤10 ms | ≤10 ms | ≤10 ms | ≤10 ms |
| Maximum load peak ratio | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| Battery & AC charging | ||||||||
| Battery system voltage | 12 V | 12 V | 12 V | 12 V | 24 V | 24 V | 24 V | 48 V |
| Battery charging voltage | 13.75 V DC | 13.75 V DC | 13.75 V DC | 13.75 V DC | 27 V DC | 27 V DC | 27 V DC | 54 V DC |
| Maximum AC charging current | 8 A | 13 A | 18 A | 30 A | 15 A | 20 A | 30 A | 15 A |
| Battery types | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries | Lead-acid, flooded and lithium batteries |
| Charging current adjustment | Selectable | Selectable | Selectable | Selectable | Selectable | Selectable | Selectable | Selectable |
| AC input | ||||||||
| Nominal AC input voltage | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) | 220 / 110 V AC (by configuration) |
| AC input voltage range | 145–275 V AC ±3 V (220 V); 73–137 V AC ±3 V (110 V) | 145–275 V AC ±3 V (220 V); 73–137 V AC ±3 V (110 V) | 145–275 V AC ±3 V (220 V); 73–137 V AC ±3 V (110 V) | 145–275 V AC ±3 V (220 V); 73–137 V AC ±3 V (110 V) | 145–275 V AC ±3 V (220 V); 73–137 V AC ±3 V (110 V) | 154–264 V AC (Normal) / 185–264 V AC (UPS) at 220 V; 77–132 V AC (Normal) / 92–132 V AC (UPS) at 110 V; ±3 V | 154–264 V AC (Normal) / 185–264 V AC (UPS) at 220 V; 77–132 V AC (Normal) / 92–132 V AC (UPS) at 110 V; ±3 V | 154–264 V AC (Normal) / 185–264 V AC (UPS) at 220 V; 77–132 V AC (Normal) / 92–132 V AC (UPS) at 110 V; ±3 V |
| Input frequency | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% | 50 / 60 Hz ±5% |
| Control & protection | ||||||||
| ECO-mode power | 6 W | 8 W | 9 W | 11 W | 12 W | 15 W | 16 W | 16 W |
| Display | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current | AC voltage / frequency, output frequency, battery voltage and load current |
| Generator control | Automatic start signal | Automatic start signal | Automatic start signal | Automatic start signal | Automatic start signal | Automatic start signal | Automatic start signal | Automatic start signal |
| Voltage regulation | AVR | AVR | AVR | AVR | AVR | AVR | AVR | AVR |
| Protection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection | Overload, short circuit, low voltage and battery reverse connection |
| Alarms | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault | Low battery, overload and fault |
| Installation | ||||||||
| Dimensions | 300 × 144 × 213 mm | 300 × 144 × 213 mm | 300 × 144 × 213 mm | 300 × 144 × 213 mm | 300 × 144 × 213 mm | 385 × 190 × 382 mm | 385 × 190 × 382 mm | 385 × 190 × 382 mm |
| Net weight | 7.5 kg | 7.9 kg | 7.8 kg | 9.1 kg | 9.1 kg | 15.4 kg | 17.9 kg | 17.9 kg |
| Operating temperature | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C | 0°C to +40°C |
| Storage temperature | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C | −15°C to +45°C |
BEFORE YOU CHOOSE
A few useful answers.
Which HB models use 12, 24 or 48 V batteries?
HB0512, HB0812, HB1012 and HB1512 use 12 V. HB1524, HB2024F and HB3024F use 24 V. HB3048F uses 48 V. Select battery voltage first, then the output power for your loads.
Is the battery built into the HB enclosure?
HB is the inverter and AC charger. It connects to an external battery bank, allowing you to choose storage capacity separately from inverter output power.
Does HB charge from solar panels directly?
HB provides AC charging. To add solar charging, use a separate solar charge controller matched to the battery bank and PV array.
Are 110 V and 220 V both available?
Yes, 110 V and 220 V AC configurations are available. Select the voltage that matches the supply and equipment in your project.
What differs between the compact and larger enclosures?
The five 400–1200 W models are listed at 300 × 144 × 213 mm. The 1600–2400 W models use the larger 385 × 190 × 382 mm enclosure. AC charging current and weight also vary by model.