IV-series 4kW–11kW Hybrid Solar Inverter with Surge Protection, Safety Switch | Techfine

IC Series · Product gallery

SOLAR + STORAGE · 4–11 kW

IC Series
Hybrid Solar Inverter

Give solar power a more controlled path through your system. IC brings accessible power switches and PV input protection together with two output circuits—so essential loads keep their place while you manage the loads that can wait.

Integrated power switches   ·   PV input protection   ·   Dual output

Explore 3 models

Select a model to see its ratings below.

6.2kWBattery-mode output
48VBattery system
8.5kWMaximum PV input

POWER CONTROL + PV PROTECTION

Bring control to the connection point.

AC, battery and PV switches put power control at the inverter. Integrated PV input protection adds a dedicated layer on the solar side, with operating information available on the front LCD.

Accessible switching

Identify the AC, battery and solar circuits at the inverter when configuring or servicing the system.

Protection on the solar path

PV input protection is integrated into the power section. Match the array to the model’s voltage and current limits.

Front LCD and power-switch access

DUAL OUTPUT

Give essential loads their own circuit.

Keep lighting and other essentials on the main output. Put loads that can wait on the second, then choose when that circuit disconnects and reconnects.

Set cut-off and recovery conditions through the output settings. SOC-based control uses a battery with compatible BMS communication.

IC dual output: normal IC dual output: normal

Both circuits are on, supplying essentials and flexible loads.

Both circuits share the inverter’s total rated output capacity.

SYSTEM OVERVIEW

Where the power goes

Use solar to power your loads and charge your battery. Bring in utility or compatible generator support when you need it.

Hybrid inverter system: solar and AC sources feed the inverter, battery storage charges and discharges, and AC power supplies the loads. Hybrid inverter system: solar and AC sources feed the inverter, battery storage charges and discharges, and AC power supplies the loads. IV-series 4kW–11kW Hybrid Solar Inverter with Surge Protection, Safety Switch | Techfine

IC SERIES

Store energy for later. Charge your battery when power is available, then draw on it during battery-powered operation.

Choose the right capacity. Match your battery capability and connected loads to the output rating of your chosen IC model.

SOLAR INPUT + EXPANSION

Choose the capacity. Plan the next step.

Start with your battery voltage and load. The two 48 V models support parallel operation, while IC11048SMH adds a second MPPT tracker for a larger solar array.

IC4024SMH

4 kW

Battery-mode output

1 MPPT · 6.5 kW PV

24 V · Standalone

IC6248SMH

6.2 kW

Battery-mode output

1 MPPT · 8.5 kW PV

48 V · Parallel capable

IC11048SMH

11 kW

Battery-mode output

2 MPPTs · 15 kW PV

48 V · Parallel capable

AC, PV, battery and communication connections

MONITORING + CONNECTIONS

Keep system information close.

Read solar, battery, AC input and output information on the LCD. Add BMS communication, WiFi or dry-contact functions through the expansion options your system needs.

THE DETAILS, SIDE BY SIDE

Technical specifications

Compare output, PV input and expansion across three IC models.

Scroll sideways to compare all models.

IC Series specifications
SpecificationIC4024SMHIC6248SMHIC11048SMH
Output
Battery-mode output4000 W6200 W11000 W
PV-mode output4500 W6500 W12000 W
Peak apparent power8000 VA12400 VA22000 VA
AC output voltage220 / 230 / 240 V AC ±5%220 / 230 / 240 V AC ±5%220 / 230 / 240 V AC ±5%
Output frequency50 / 60 Hz ±0.1%50 / 60 Hz ±0.1%50 / 60 Hz ±0.1%
Output waveformPure sine wavePure sine wavePure sine wave
Transfer time10 ms (computer equipment); 20 ms (household equipment)10 ms (computer equipment); 20 ms (household equipment)10 ms (computer equipment); 20 ms (household equipment)
AC outputsMain output + controlled second outputMain output + controlled second outputMain output + controlled second output
Solar input
Maximum PV input power6500 W8500 W15000 W
MPPT trackers112
Maximum PV input current27 A27 A27 + 27 A
MPPT voltage range60–500 V DC60–500 V DC90–500 V DC
Recommended PV operating voltage360–430 V DC360–430 V DC360–430 V DC
Maximum PV open-circuit voltage500 V DC500 V DC500 V DC
Battery & charging
Battery system voltage24 V48 V48 V
Constant-voltage charge setting28.2 V (configurable)56.4 V (configurable)56.4 V (configurable)
Float charge setting27 V (configurable)54 V (configurable)54 V (configurable)
Maximum solar charging current120 A120 A150 A
Maximum AC charging current100 A100 A150 A
Maximum combined charging current120 A120 A150 A
AC input & grid
Nominal AC input220 / 230 / 240 V AC220 / 230 / 240 V AC220 / 230 / 240 V AC
Normal input voltage range90–280 V AC ±3 V90–280 V AC ±3 V90–280 V AC ±3 V
UPS input voltage range170–280 V AC ±3 V170–280 V AC ±3 V170–280 V AC ±3 V
Input frequency50 / 60 Hz (auto-sensing)50 / 60 Hz (auto-sensing)50 / 60 Hz (auto-sensing)
Grid-connected output voltage220 / 230 / 240 V AC220 / 230 / 240 V AC220 / 230 / 240 V AC
Grid feed-in voltage range100–280 V AC100–280 V AC100–280 V AC
Nominal grid output current17.4 A26.9 A47.8 A
Grid power factor>0.99>0.99>0.99
Maximum DC/AC conversion efficiency98%98%98%
Control & expansion
DisplayLCDLCDLCD
CommunicationRS232 · 2400 baudRS232 · 2400 baudRS232 · 2400 baud
Expansion optionsBMS / WiFi / dry contactBMS / WiFi / dry contactBMS / WiFi / dry contact
Parallel operationNot supportedSupportedSupported
Power controlAC / battery / PV switches with PV input protectionAC / battery / PV switches with PV input protectionAC / battery / PV switches with PV input protection
Installation
Dimensions (L × W × H)483 × 313 × 143 mm483 × 313 × 143 mm483 × 313 × 143 mm
Operating temperature−10°C to +50°C−10°C to +50°C−10°C to +50°C
Storage temperature−15°C to +60°C−15°C to +60°C−15°C to +60°C
Operating humidity20–95% RH (non-condensing)20–95% RH (non-condensing)20–95% RH (non-condensing)
Noise≤50 dB≤50 dB≤50 dB

BEFORE YOU CHOOSE

A few useful answers.

What are the two outputs for?

Keep essential loads on the main output and place less urgent loads on the second circuit. Configure when the second output disconnects and reconnects as battery conditions change. Both circuits share the inverter’s total rated output capacity.

Which IC models support parallel operation?

IC6248SMH and IC11048SMH support parallel operation. The 24 V IC4024SMH is for standalone operation. Use matching supported inverters and the required parallel configuration.

Does every IC model have two MPPT trackers?

No. IC4024SMH and IC6248SMH each have one MPPT tracker. IC11048SMH has two trackers, with 27 A per input and 15 kW total maximum PV input power.

Which output rating should I use for battery backup?

Use the battery-mode output: 4, 6.2 or 11 kW, depending on model. PV-mode output is listed separately as 4.5, 6.5 or 12 kW. Size the connected battery and load together for backup operation.

Can I add battery communication or WiFi?

BMS communication, WiFi and dry-contact functions are available as expansion options. Choose the required modules with the inverter. For SOC-based battery control, use compatible BMS communication and configure the battery settings.

Let’s build your energy system.