IC Series · Product gallery
SOLAR + STORAGE · 4–11 kW
IC Series
Hybrid Solar Inverter
Give solar power a more controlled path through your system. IC brings accessible power switches and PV input protection together with two output circuits—so essential loads keep their place while you manage the loads that can wait.
Integrated power switches · PV input protection · Dual output
Select a model to see its ratings below.
POWER CONTROL + PV PROTECTION
Bring control to the connection point.
AC, battery and PV switches put power control at the inverter. Integrated PV input protection adds a dedicated layer on the solar side, with operating information available on the front LCD.
Accessible switching
Identify the AC, battery and solar circuits at the inverter when configuring or servicing the system.
Protection on the solar path
PV input protection is integrated into the power section. Match the array to the model’s voltage and current limits.
Front LCD and power-switch access
DUAL OUTPUT
Give essential loads their own circuit.
Keep lighting and other essentials on the main output. Put loads that can wait on the second, then choose when that circuit disconnects and reconnects.
Set cut-off and recovery conditions through the output settings. SOC-based control uses a battery with compatible BMS communication.
Both circuits are on, supplying essentials and flexible loads.
The main circuit stays on. The second pauses at your chosen cut-off condition.
The second circuit reconnects when its recovery condition is reached.
Both circuits share the inverter’s total rated output capacity.
SYSTEM OVERVIEW
Where the power goes
Use solar to power your loads and charge your battery. Bring in utility or compatible generator support when you need it.
IC SERIES
Store energy for later. Charge your battery when power is available, then draw on it during battery-powered operation.
Choose the right capacity. Match your battery capability and connected loads to the output rating of your chosen IC model.
SOLAR INPUT + EXPANSION
Choose the capacity. Plan the next step.
Start with your battery voltage and load. The two 48 V models support parallel operation, while IC11048SMH adds a second MPPT tracker for a larger solar array.
IC4024SMH
4 kW
Battery-mode output
1 MPPT · 6.5 kW PV
24 V · Standalone
IC6248SMH
6.2 kW
Battery-mode output
1 MPPT · 8.5 kW PV
48 V · Parallel capable
IC11048SMH
11 kW
Battery-mode output
2 MPPTs · 15 kW PV
48 V · Parallel capable
AC, PV, battery and communication connections
MONITORING + CONNECTIONS
Keep system information close.
Read solar, battery, AC input and output information on the LCD. Add BMS communication, WiFi or dry-contact functions through the expansion options your system needs.
THE DETAILS, SIDE BY SIDE
Technical specifications
Compare output, PV input and expansion across three IC models.
Scroll sideways to compare all models.
| Specification | IC4024SMH | IC6248SMH | IC11048SMH |
|---|---|---|---|
| Output | |||
| Battery-mode output | 4000 W | 6200 W | 11000 W |
| PV-mode output | 4500 W | 6500 W | 12000 W |
| Peak apparent power | 8000 VA | 12400 VA | 22000 VA |
| AC output voltage | 220 / 230 / 240 V AC ±5% | 220 / 230 / 240 V AC ±5% | 220 / 230 / 240 V AC ±5% |
| Output frequency | 50 / 60 Hz ±0.1% | 50 / 60 Hz ±0.1% | 50 / 60 Hz ±0.1% |
| Output waveform | Pure sine wave | Pure sine wave | Pure sine wave |
| Transfer time | 10 ms (computer equipment); 20 ms (household equipment) | 10 ms (computer equipment); 20 ms (household equipment) | 10 ms (computer equipment); 20 ms (household equipment) |
| AC outputs | Main output + controlled second output | Main output + controlled second output | Main output + controlled second output |
| Solar input | |||
| Maximum PV input power | 6500 W | 8500 W | 15000 W |
| MPPT trackers | 1 | 1 | 2 |
| Maximum PV input current | 27 A | 27 A | 27 + 27 A |
| MPPT voltage range | 60–500 V DC | 60–500 V DC | 90–500 V DC |
| Recommended PV operating voltage | 360–430 V DC | 360–430 V DC | 360–430 V DC |
| Maximum PV open-circuit voltage | 500 V DC | 500 V DC | 500 V DC |
| Battery & charging | |||
| Battery system voltage | 24 V | 48 V | 48 V |
| Constant-voltage charge setting | 28.2 V (configurable) | 56.4 V (configurable) | 56.4 V (configurable) |
| Float charge setting | 27 V (configurable) | 54 V (configurable) | 54 V (configurable) |
| Maximum solar charging current | 120 A | 120 A | 150 A |
| Maximum AC charging current | 100 A | 100 A | 150 A |
| Maximum combined charging current | 120 A | 120 A | 150 A |
| AC input & grid | |||
| Nominal AC input | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC |
| Normal input voltage range | 90–280 V AC ±3 V | 90–280 V AC ±3 V | 90–280 V AC ±3 V |
| UPS input voltage range | 170–280 V AC ±3 V | 170–280 V AC ±3 V | 170–280 V AC ±3 V |
| Input frequency | 50 / 60 Hz (auto-sensing) | 50 / 60 Hz (auto-sensing) | 50 / 60 Hz (auto-sensing) |
| Grid-connected output voltage | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC |
| Grid feed-in voltage range | 100–280 V AC | 100–280 V AC | 100–280 V AC |
| Nominal grid output current | 17.4 A | 26.9 A | 47.8 A |
| Grid power factor | >0.99 | >0.99 | >0.99 |
| Maximum DC/AC conversion efficiency | 98% | 98% | 98% |
| Control & expansion | |||
| Display | LCD | LCD | LCD |
| Communication | RS232 · 2400 baud | RS232 · 2400 baud | RS232 · 2400 baud |
| Expansion options | BMS / WiFi / dry contact | BMS / WiFi / dry contact | BMS / WiFi / dry contact |
| Parallel operation | Not supported | Supported | Supported |
| Power control | AC / battery / PV switches with PV input protection | AC / battery / PV switches with PV input protection | AC / battery / PV switches with PV input protection |
| Installation | |||
| Dimensions (L × W × H) | 483 × 313 × 143 mm | 483 × 313 × 143 mm | 483 × 313 × 143 mm |
| Operating temperature | −10°C to +50°C | −10°C to +50°C | −10°C to +50°C |
| Storage temperature | −15°C to +60°C | −15°C to +60°C | −15°C to +60°C |
| Operating humidity | 20–95% RH (non-condensing) | 20–95% RH (non-condensing) | 20–95% RH (non-condensing) |
| Noise | ≤50 dB | ≤50 dB | ≤50 dB |
BEFORE YOU CHOOSE
A few useful answers.
What are the two outputs for?
Keep essential loads on the main output and place less urgent loads on the second circuit. Configure when the second output disconnects and reconnects as battery conditions change. Both circuits share the inverter’s total rated output capacity.
Which IC models support parallel operation?
IC6248SMH and IC11048SMH support parallel operation. The 24 V IC4024SMH is for standalone operation. Use matching supported inverters and the required parallel configuration.
Does every IC model have two MPPT trackers?
No. IC4024SMH and IC6248SMH each have one MPPT tracker. IC11048SMH has two trackers, with 27 A per input and 15 kW total maximum PV input power.
Which output rating should I use for battery backup?
Use the battery-mode output: 4, 6.2 or 11 kW, depending on model. PV-mode output is listed separately as 4.5, 6.5 or 12 kW. Size the connected battery and load together for backup operation.
Can I add battery communication or WiFi?
BMS communication, WiFi and dry-contact functions are available as expansion options. Choose the required modules with the inverter. For SOC-based battery control, use compatible BMS communication and configure the battery settings.