LA Series · Product view
INVERTER + BATTERY · ONE COMPLETE SYSTEM
LA Series
Solar + Storage System
Solar conversion and stored energy, together in a floor-standing system. LA pairs a 6.2 or 11 kW inverter with an included LiFePO4 battery, giving you a clear starting point for daytime solar use and stored power after sunset.
Inverter included · LiFePO4 battery included · Expandable storage
Select a model to see its ratings below.
THE COMPLETE SYSTEM
The inverter above.
Your energy reserve below.
LA combines the inverter and LiFePO4 storage in a floor-standing format. Solar power can run your loads and recharge the battery; stored energy is ready when you need battery-powered operation.
Both the inverter and battery are included in each LA configuration.
UPPER MODULE
Inverter
6.2 or 11 kW AC output
LOWER MODULE
Battery
5.12 or 11.776 kWh included
POWER + STORED ENERGY
Choose the load capacity.
Then the energy reserve.
Inverter power and battery energy answer different questions. Size the inverter for equipment running together, and choose storage for the hours you want it to cover.
The battery’s discharge-current limit also sets how much power can come from storage.
LA6248SMHG
6.2 kW
Rated inverter output
5.12 kWh
Included battery energy
Solar input 8.5 kW
Battery 51.2 V LiFePO4
Continuous battery discharge 100 A
LA11048SMHG
11 kW
Rated inverter output
11.776 kWh
Included battery energy
Solar input 15 kW · 2 × 7.5 kW
Battery 51.2 V LiFePO4
Continuous battery discharge 200 A
EXPANDABLE BATTERY STORAGE
Add energy without changing system voltage
Add matching battery modules in parallel as your storage needs grow. The battery system remains at 51.2 V; the supported bank can contain up to 15 matching modules.
Plan the module placement, cables and inverter charging settings together.
Up to 15
Matching battery modules
51.2 V
System voltage in parallel
STATUS + CONTROL
Know the charge.
Choose the supply priority.
BATTERY STATUS
SOC, RUN and ALM
Six SOC indicators show the battery charge range. RUN and ALM separate normal operation from an alarm state.
BMS COMMUNICATION
RS485 / CAN
The battery exchanges operating information with the inverter through compatible BMS communication.
SUPPLY CONTROL
Choose the priority
Select PV, utility or battery priority for your system. Grid feed-in is an optional configuration.
THE DETAILS, SIDE BY SIDE
Technical specifications
Compare 2 configurations by output, solar input and included storage.
Scroll sideways to compare all models.
| Specification | LA6248SMHG | LA11048SMHG |
|---|---|---|
| System configuration | ||
| Package | Inverter + LiFePO4 battery | Inverter + LiFePO4 battery |
| Rated inverter output power | 6200 W | 11000 W |
| Included battery energy | 5120 Wh | 11776 Wh |
| Rated battery voltage | 51.2 V | 51.2 V |
| Battery chemistry | LiFePO4 | LiFePO4 |
| Inverter output | ||
| Nominal output voltage | 230 V AC ±5% | 230 V AC ±5% |
| Output waveform | Pure sine wave | Pure sine wave |
| Peak apparent power | 11000 VA | 22000 VA |
| Output frequency | 50 / 60 Hz ±0.1% | 50 / 60 Hz ±0.1% |
| Maximum efficiency | 98% | 98% |
| Transfer time | 10 ms (computer equipment); 30 ms (household equipment) | 10 ms (computer equipment); 30 ms (household equipment) |
| AC input | ||
| Nominal input voltage | 230 V AC | 230 V AC |
| Input voltage range | 170–280 V AC (UPS); 90–280 V AC (inverter mode) | 170–280 V AC (UPS); 90–280 V AC (inverter mode) |
| Input frequency | 50 / 60 Hz (auto-sensing) | 50 / 60 Hz (auto-sensing) |
| Solar input | ||
| Maximum PV input power | 8500 W | 15000 W (2 × 7500 W) |
| Charging controller | MPPT | MPPT |
| MPPT voltage range | 90–500 V DC | 90–500 V DC |
| Maximum solar charging current | 120 A | 150 A |
| Maximum AC charging current | 60 A | 150 A |
| Maximum combined charging current | 120 A | 150 A |
| Included battery | ||
| Full-charge / full-discharge voltage | 56 / 42 V DC | 56 / 42 V DC |
| Maximum continuous discharge current | 100 A | 200 A |
| Maximum one-minute discharge current | 120 A | 230 A |
| Recommended charging current | 50 A (0.5C) | 115 A (0.5C) |
| Maximum battery charging current | 100 A | 200 A |
| Battery management | BMS with relay | BMS with relay |
| Battery communication | RS485 / CAN | RS485 / CAN |
| Parallel battery expansion | Up to 15 matching battery modules | Up to 15 matching battery modules |
| Battery status indicators | Six-step SOC, RUN and ALM | Six-step SOC, RUN and ALM |
| Control & installation | ||
| Power priorities | PV priority / utility priority / battery priority | PV priority / utility priority / battery priority |
| Grid feed-in | Optional configuration | Optional configuration |
| Inverter dimensions (L × W × H) | 610 × 170 × 370 mm | 630 × 250 × 475 mm |
| Battery dimensions (L × W × H) | 610 × 170 × 490 mm | 630 × 250 × 525 mm |
| Installation | Floor-standing with base and wall fixing | Floor-standing with base and wall fixing |
BEFORE YOU CHOOSE
A few useful answers.
Does LA include both the inverter and battery?
Yes. LA is supplied as an inverter-and-battery system. LA6248SMHG combines a 6.2 kW inverter with 5.12 kWh of battery energy. LA11048SMHG combines an 11 kW inverter with 11.776 kWh. Both use a 51.2 V LiFePO4 battery.
What is the difference between kW and kWh?
kW describes power at a moment in time; kWh describes stored energy. Choose inverter power for loads that run together and battery energy for how long you want stored power to last. Battery current limits also determine the power available from storage.
Can I add more battery capacity?
Yes. Matching LA battery modules support parallel expansion, up to 15 modules in a compatible bank. Parallel batteries retain the same system voltage. Confirm the physical arrangement and inverter settings when adding modules.
How much solar can I connect?
The 6.2 kW system accepts up to 8.5 kW of PV input. The 11 kW system accepts 2 × 7.5 kW, or 15 kW total. Size the solar array to its input limits and set charging current to suit the complete battery bank.
Is exporting solar to the grid standard?
Grid feed-in is an optional LA configuration. Select that option when ordering a grid-export system. The standard system already combines solar conversion, AC supply and battery storage with selectable supply priorities.