LA Series inverter and battery system

LA Series · Product view

INVERTER + BATTERY · ONE COMPLETE SYSTEM

LA Series
Solar + Storage System

Solar conversion and stored energy, together in a floor-standing system. LA pairs a 6.2 or 11 kW inverter with an included LiFePO4 battery, giving you a clear starting point for daytime solar use and stored power after sunset.

Inverter included   ·   LiFePO4 battery included   ·   Expandable storage

Explore 2 models

Select a model to see its ratings below.

6.2kWInverter output
5.12kWhIncluded storage
8.5kWMaximum PV input

THE COMPLETE SYSTEM

The inverter above.
Your energy reserve below.

LA combines the inverter and LiFePO4 storage in a floor-standing format. Solar power can run your loads and recharge the battery; stored energy is ready when you need battery-powered operation.

Both the inverter and battery are included in each LA configuration.

LA Series inverter and battery system

UPPER MODULE

Inverter

6.2 or 11 kW AC output

LOWER MODULE

Battery

5.12 or 11.776 kWh included

POWER + STORED ENERGY

Choose the load capacity.
Then the energy reserve.

Inverter power and battery energy answer different questions. Size the inverter for equipment running together, and choose storage for the hours you want it to cover.

The battery’s discharge-current limit also sets how much power can come from storage.

LA6248SMHG

6.2 kW

Rated inverter output

5.12 kWh

Included battery energy

Solar input   8.5 kW

Battery   51.2 V LiFePO4

Continuous battery discharge   100 A

EXPANDABLE BATTERY STORAGE

Add energy without changing system voltage

Add matching battery modules in parallel as your storage needs grow. The battery system remains at 51.2 V; the supported bank can contain up to 15 matching modules.

Plan the module placement, cables and inverter charging settings together.

Up to 15

Matching battery modules

51.2 V

System voltage in parallel

STATUS + CONTROL

Know the charge.
Choose the supply priority.

BATTERY STATUS

SOC, RUN and ALM

Six SOC indicators show the battery charge range. RUN and ALM separate normal operation from an alarm state.

BMS COMMUNICATION

RS485 / CAN

The battery exchanges operating information with the inverter through compatible BMS communication.

SUPPLY CONTROL

Choose the priority

Select PV, utility or battery priority for your system. Grid feed-in is an optional configuration.

THE DETAILS, SIDE BY SIDE

Technical specifications

Compare 2 configurations by output, solar input and included storage.

Scroll sideways to compare all models.

LA-series specifications
SpecificationLA6248SMHGLA11048SMHG
System configuration
PackageInverter + LiFePO4 batteryInverter + LiFePO4 battery
Rated inverter output power6200 W11000 W
Included battery energy5120 Wh11776 Wh
Rated battery voltage51.2 V51.2 V
Battery chemistryLiFePO4LiFePO4
Inverter output
Nominal output voltage230 V AC ±5%230 V AC ±5%
Output waveformPure sine wavePure sine wave
Peak apparent power11000 VA22000 VA
Output frequency50 / 60 Hz ±0.1%50 / 60 Hz ±0.1%
Maximum efficiency98%98%
Transfer time10 ms (computer equipment); 30 ms (household equipment)10 ms (computer equipment); 30 ms (household equipment)
AC input
Nominal input voltage230 V AC230 V AC
Input voltage range170–280 V AC (UPS); 90–280 V AC (inverter mode)170–280 V AC (UPS); 90–280 V AC (inverter mode)
Input frequency50 / 60 Hz (auto-sensing)50 / 60 Hz (auto-sensing)
Solar input
Maximum PV input power8500 W15000 W (2 × 7500 W)
Charging controllerMPPTMPPT
MPPT voltage range90–500 V DC90–500 V DC
Maximum solar charging current120 A150 A
Maximum AC charging current60 A150 A
Maximum combined charging current120 A150 A
Included battery
Full-charge / full-discharge voltage56 / 42 V DC56 / 42 V DC
Maximum continuous discharge current100 A200 A
Maximum one-minute discharge current120 A230 A
Recommended charging current50 A (0.5C)115 A (0.5C)
Maximum battery charging current100 A200 A
Battery managementBMS with relayBMS with relay
Battery communicationRS485 / CANRS485 / CAN
Parallel battery expansionUp to 15 matching battery modulesUp to 15 matching battery modules
Battery status indicatorsSix-step SOC, RUN and ALMSix-step SOC, RUN and ALM
Control & installation
Power prioritiesPV priority / utility priority / battery priorityPV priority / utility priority / battery priority
Grid feed-inOptional configurationOptional configuration
Inverter dimensions (L × W × H)610 × 170 × 370 mm630 × 250 × 475 mm
Battery dimensions (L × W × H)610 × 170 × 490 mm630 × 250 × 525 mm
InstallationFloor-standing with base and wall fixingFloor-standing with base and wall fixing

BEFORE YOU CHOOSE

A few useful answers.

Does LA include both the inverter and battery?

Yes. LA is supplied as an inverter-and-battery system. LA6248SMHG combines a 6.2 kW inverter with 5.12 kWh of battery energy. LA11048SMHG combines an 11 kW inverter with 11.776 kWh. Both use a 51.2 V LiFePO4 battery.

What is the difference between kW and kWh?

kW describes power at a moment in time; kWh describes stored energy. Choose inverter power for loads that run together and battery energy for how long you want stored power to last. Battery current limits also determine the power available from storage.

Can I add more battery capacity?

Yes. Matching LA battery modules support parallel expansion, up to 15 modules in a compatible bank. Parallel batteries retain the same system voltage. Confirm the physical arrangement and inverter settings when adding modules.

How much solar can I connect?

The 6.2 kW system accepts up to 8.5 kW of PV input. The 11 kW system accepts 2 × 7.5 kW, or 15 kW total. Size the solar array to its input limits and set charging current to suit the complete battery bank.

Is exporting solar to the grid standard?

Grid feed-in is an optional LA configuration. Select that option when ordering a grid-export system. The standard system already combines solar conversion, AC supply and battery storage with selectable supply priorities.

Let’s build your energy system.

Tell us about your system and the model you have in mind.

Discuss your project

Leave a message.