M Series · Product gallery
SOLAR CHARGING · 40–120 A
M Series
MPPT Solar Charge Controller
Turn solar generation into controlled battery charging. M brings 40–120 A choices, adaptive 12 / 24 / 36 / 48 V models and dedicated 96 V models into one range—with charge settings at your fingertips.
Three-stage charging · Backlit LCD · Adjustable parameters
Select a model to see its ratings below.
TWO SYSTEM VOLTAGE GROUPS
Choose around your battery bank
The adaptive models cover four common battery voltages. Dedicated 96 V models serve higher-voltage storage. Each group has its own PV voltage and DC load-output capabilities.
12 / 24 / 36 / 48 V
40415 · 60415 · 80415 · 100415 · 120415
40–120 A
Rated charging current
150 V DC
Maximum PV open-circuit voltage
40 A DC load output · on/off, time and light control
96 V
60825 · 80825 · 100825
60 / 80 / 100 A
Rated charging current
250 V DC
Maximum PV open-circuit voltage
Dedicated battery charging · no DC load output
SYSTEM OVERVIEW
Where the power goes
Bring PV power into the controller, charge the battery in controlled stages, and use the DC load output on the adaptive 12–48 V models.
M SERIES
Charge for later. Store solar energy in your battery with charging parameters matched to its chemistry and voltage.
Need AC power? Add a separate inverter to your battery system. The M controller handles solar charging; the inverter supplies AC loads.
THREE-STAGE CHARGING
Control the charge,
stage by stage.
Set the battery parameters at the front panel. The charging sequence manages current first, then voltage, before moving to float.
M Series · Front-panel display and setting controls
01
Constant current
Charge within the configured current limit.
02
Constant voltage
Hold the target charging voltage as charge current changes.
03
Float
Maintain the configured float voltage after the main charge.
Match charging voltage and current to the battery chemistry and battery manufacturer’s settings.
THE DETAILS, SIDE BY SIDE
Technical specifications
Compare 8 models by charging current, battery voltage, solar input and load output.
Scroll sideways to compare all models.
| Specification | 40415 | 60415 | 80415 | 100415 | 120415 | 60825 | 80825 | 100825 |
|---|---|---|---|---|---|---|---|---|
| Charging | ||||||||
| Rated charging current | 40 A | 60 A | 80 A | 100 A | 120 A | 60 A | 80 A | 100 A |
| Battery system voltage | 12 / 24 / 36 / 48 V (adaptive) | 12 / 24 / 36 / 48 V (adaptive) | 12 / 24 / 36 / 48 V (adaptive) | 12 / 24 / 36 / 48 V (adaptive) | 12 / 24 / 36 / 48 V (adaptive) | 96 V | 96 V | 96 V |
| Charging mode | MPPT | MPPT | MPPT | MPPT | MPPT | MPPT | MPPT | MPPT |
| Charging stages | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float | Constant current → constant voltage → float |
| Battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types | Sealed, gel and flooded lead-acid; configurable parameters for other battery types |
| Lithium battery charging | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters | Supported with suitable battery charging parameters |
| MPPT tracking efficiency | ≥99.5% | ≥99.5% | ≥99.5% | ≥99.5% | ≥99.5% | ≥99.5% | ≥99.5% | ≥99.5% |
| Conversion efficiency | 85–97% | 85–97% | 85–97% | 85–97% | 85–97% | 85–97% | 85–97% | 85–97% |
| System identification voltage range | 10–64 V | 10–64 V | 10–64 V | 10–64 V | 10–64 V | 72–128 V | 72–128 V | 72–128 V |
| PV input | ||||||||
| Maximum PV open-circuit voltage | 150 V DC | 150 V DC | 150 V DC | 150 V DC | 150 V DC | 250 V DC | 250 V DC | 250 V DC |
| MPPT operating range | 18–150 V DC at 12 V; 36–150 V DC at 24 V; 48–150 V DC at 36 V; 64–150 V DC at 48 V | 18–150 V DC at 12 V; 36–150 V DC at 24 V; 48–150 V DC at 36 V; 64–150 V DC at 48 V | 18–150 V DC at 12 V; 36–150 V DC at 24 V; 48–150 V DC at 36 V; 64–150 V DC at 48 V | 18–150 V DC at 12 V; 36–150 V DC at 24 V; 48–150 V DC at 36 V; 64–150 V DC at 48 V | 18–150 V DC at 12 V; 36–150 V DC at 24 V; 48–150 V DC at 36 V; 64–150 V DC at 48 V | 128–250 V DC | 128–250 V DC | 128–250 V DC |
| Rated charging power | ||||||||
| At 12 V | 540 W | 800 W | 1040 W | 1300 W | 1560 W | — | — | — |
| At 24 V | 1080 W | 1600 W | 2080 W | 2600 W | 3120 W | — | — | — |
| At 36 V | 1620 W | 2400 W | 3120 W | 3900 W | 4680 W | — | — | — |
| At 48 V | 2160 W | 3200 W | 4160 W | 5200 W | 6240 W | — | — | — |
| At 96 V | — | — | — | — | — | 6240 W | 8320 W | 10400 W |
| DC load output | ||||||||
| Load output | Supported; same voltage as battery | Supported; same voltage as battery | Supported; same voltage as battery | Supported; same voltage as battery | Supported; same voltage as battery | Not available | Not available | Not available |
| Rated load current | 40 A | 40 A | 40 A | 40 A | 40 A | — | — | — |
| Load control | On / off, time control and light control | On / off, time control and light control | On / off, time control and light control | On / off, time control and light control | On / off, time control and light control | Not available | Not available | Not available |
| Control & performance | ||||||||
| Display | Backlit LCD | Backlit LCD | Backlit LCD | Backlit LCD | Backlit LCD | Backlit LCD | Backlit LCD | Backlit LCD |
| Settings | Front-panel buttons | Front-panel buttons | Front-panel buttons | Front-panel buttons | Front-panel buttons | Front-panel buttons | Front-panel buttons | Front-panel buttons |
| Remote monitoring | WiFi support | WiFi support | WiFi support | WiFi support | WiFi support | WiFi support | WiFi support | WiFi support |
| Starting time | ≤10 s | ≤10 s | ≤10 s | ≤10 s | ≤10 s | ≤10 s | ≤10 s | ≤10 s |
| Dynamic response recovery | ≤500 µs | ≤500 µs | ≤500 µs | ≤500 µs | ≤500 µs | ≤500 µs | ≤500 µs | ≤500 µs |
| Static power | ≤4 W | ≤4 W | ≤8 W | ≤8 W | ≤8 W | ≤4 W | ≤8 W | ≤8 W |
| Cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling | Air cooling |
| Protection | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent | Input / output over- and undervoltage; reverse polarity; overtemperature; load overcurrent |
| Installation | ||||||||
| Dimensions | 219 × 260 × 110 mm | 219 × 260 × 110 mm | 274 × 350 × 110 mm | 274 × 350 × 110 mm | 274 × 350 × 110 mm | 219 × 260 × 110 mm | 275 × 348 × 109 mm | 275 × 348 × 109 mm |
| Net weight | 2.8 kg | 2.8 kg | 4.6 kg | 5.2 kg | 5.2 kg | 2.8 kg | 4.6 kg | 5.2 kg |
| Operating temperature | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C | −20°C to +50°C |
| Storage temperature | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C | −30°C to +70°C |
| Humidity | 0–90% RH | 0–90% RH | 0–90% RH | 0–90% RH | 0–90% RH | 0–90% RH | 0–90% RH | 0–90% RH |
| Operating altitude | 0–3000 m | 0–3000 m | 0–3000 m | 0–3000 m | 0–3000 m | 0–3000 m | 0–3000 m | 0–3000 m |
| Noise | ≤50 dB | ≤50 dB | ≤50 dB | ≤50 dB | ≤50 dB | ≤50 dB | ≤50 dB | ≤50 dB |
BEFORE YOU CHOOSE
A few useful answers.
Is M an inverter or a charge controller?
M is an MPPT solar charge controller. It regulates power from the PV array to charge the battery. Use a separate inverter when you need to supply AC equipment.
Which models adapt to battery voltage?
40415, 60415, 80415, 100415 and 120415 support adaptive 12 / 24 / 36 / 48 V systems. 60825, 80825 and 100825 are dedicated 96 V models.
How much solar charging power can I use?
The rating depends on both controller size and battery voltage. For example, 60415 is rated at 800 W at 12 V, 1600 W at 24 V, 2400 W at 36 V and 3200 W at 48 V. Use the matching row in the specification table.
Do all models have a DC load output?
The five adaptive 12–48 V models have a 40 A DC load output at battery voltage, with on/off, time and light control. The three 96 V models do not have a load output.
Can I adjust charging for my battery?
Yes. Use the front-panel buttons to set charging parameters. The controller supports three-stage charging and battery-specific settings, including suitable settings for lithium batteries. The backlit LCD shows operating information.