TH Series · Product view
IP54 HYBRID POWER · 4–11 kW
TH Series
Hybrid Solar Inverter
Keep essential loads in priority—and leave room to grow. TH pairs an IP54 enclosure with a controlled second output, so less urgent loads can pause as battery charge falls. Choose a 48 V model to build a larger system with up to 12 matching inverters.
IP54 enclosure · Controlled second output · 48 V parallel expansion
Select a model to see its ratings below.
IP54 ENCLOSURE
Protected outside.
Controlled inside.
An IP54 enclosure brings dust and splash protection to the inverter. Inside, solar charging and a controlled second output work together to keep essential loads in priority.
IP54
Enclosure protection
2 outputs
Main + controlled second circuit
DUAL OUTPUT
Give essentials their own circuit.
Keep lighting and essential appliances on the main output. Put less urgent loads on the second circuit, then set when it disconnects and reconnects as battery conditions change.
Control the second output by battery voltage or SOC. For SOC-based control, connect a compatible battery and enable BMS communication.
TH Series
OUTPUT 01
ON
Main output
Lighting & essentials
OUTPUT 02
ON
Second output
Loads that can wait
Both circuits supply their connected loads.
TH Series
OUTPUT 01
ON
Main output
Lighting & essentials
OUTPUT 02
PAUSED
Second output
Loads that can wait
The main output stays on while less urgent loads pause.
TH Series
OUTPUT 01
ON
Main output
Lighting & essentials
OUTPUT 02
ON
Second output
Loads that can wait
The second circuit reconnects at its recovery threshold.
Both output circuits share the inverter’s total rated capacity.
SYSTEM OVERVIEW
Where the power goes
Use solar to power your loads and charge your battery. Bring in utility or compatible generator support when you need it.
TH SERIES
Store energy for later. Charge your battery when power is available, then draw on it during battery-powered operation.
Choose the right capacity. Match your battery capability and connected loads to the output rating of your chosen TH model.
48 V PARALLEL EXPANSION
Start with one.
Build toward twelve.
TH6248SMH and TH11048SMH support up to 12 matching inverters in parallel. TH4024SMH is the standalone 24 V option.
Up to 12
Matching inverters
15 kW
PV input on TH11048SMH
Matching 48 V units · One expanded system
DISPLAY + COMMUNICATION
Check the system. Choose your connections.
Use the front display for everyday checks, then add the communication options your system needs.
Front LCD
Check solar input, battery condition, load and AC status from the front panel.
Battery communication
Add lithium BMS communication to use battery status in supported controls.
WiFi monitoring
Choose the optional WiFi module to check system information remotely.
THE DETAILS, SIDE BY SIDE
Technical specifications
Compare output, battery voltage and solar input across 3 TH models.
Scroll sideways to compare all models.
| Specification | TH4024SMH | TH6248SMH | TH11048SMH |
|---|---|---|---|
| Output | |||
| Battery-mode output | 4000 W | 6200 W | 11000 W |
| PV-mode output | 4500 W | 6500 W | 12000 W |
| Peak apparent power | 8000 VA | 12400 VA | 22000 VA |
| AC output voltage | 220 / 230 / 240 V AC ±5% | 220 / 230 / 240 V AC ±5% | 220 / 230 / 240 V AC ±5% |
| Output waveform | Pure sine wave | Pure sine wave | Pure sine wave |
| Transfer time | 10 ms (computer equipment); 20 ms (household equipment) | 10 ms (computer equipment); 20 ms (household equipment) | 10 ms (computer equipment); 20 ms (household equipment) |
| Solar input | |||
| Maximum PV input power | 6500 W | 8500 W | 15000 W |
| MPPT trackers | 1 | 1 | 2 |
| Maximum PV input current | 27 A | 27 A | 27 + 27 A |
| PV input voltage range | 60–500 V DC | 60–500 V DC | 90–500 V DC |
| Maximum PV open-circuit voltage | 500 V DC | 500 V DC | 500 V DC |
| Battery & charging | |||
| Battery system voltage | 24 V | 48 V | 48 V |
| Constant-voltage charge setting | 28.2 V DC | 56.4 V DC | 56.4 V DC |
| Float charge setting | 27 V DC | 54 V DC | 54 V DC |
| Maximum solar charging current | 120 A | 120 A | 150 A |
| Maximum AC charging current | 100 A | 100 A | 150 A |
| Maximum combined charging current | 120 A | 120 A | 150 A |
| AC input & grid | |||
| Nominal AC input | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC |
| Normal input voltage range | 90–280 V AC ±3 V | 90–280 V AC ±3 V | 90–280 V AC ±3 V |
| UPS input voltage range | 170–280 V AC ±3 V | 170–280 V AC ±3 V | 170–280 V AC ±3 V |
| Input frequency | 50 / 60 Hz (auto-sensing) | 50 / 60 Hz (auto-sensing) | 50 / 60 Hz (auto-sensing) |
| Grid-connected output voltage | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC | 220 / 230 / 240 V AC |
| Nominal grid output current | 17.4 A | 26.9 A | 47.8 A |
| Grid power factor | >0.99 | >0.99 | >0.99 |
| Maximum DC/AC conversion efficiency | 98% | 98% | 98% |
| Grid feed-in voltage range | 180–280 V AC | 180–280 V AC | 180–280 V AC |
| Output frequency | 50 / 60 Hz ±0.1% | 50 / 60 Hz ±0.1% | 50 / 60 Hz ±0.1% |
| Control & expansion | |||
| AC outputs | Main output + controlled second output | Main output + controlled second output | Main output + controlled second output |
| Second-output control | Battery voltage or SOC; SOC requires compatible BMS communication | Battery voltage or SOC; SOC requires compatible BMS communication | Battery voltage or SOC; SOC requires compatible BMS communication |
| Display | LCD | LCD | LCD |
| Communication | RS232 · 2400 baud | RS232 · 2400 baud | RS232 · 2400 baud |
| Expansion options | Lithium BMS communication / WiFi | Lithium BMS communication / WiFi | Lithium BMS communication / WiFi |
| Parallel operation | Not supported | Up to 12 matching units | Up to 12 matching units |
| Installation | |||
| Enclosure protection | IP54 | IP54 | IP54 |
| Operating temperature | −10°C to +50°C | −10°C to +50°C | −10°C to +50°C |
| Storage temperature | −15°C to +60°C | −15°C to +60°C | −15°C to +60°C |
| Operating humidity | 20–95% RH (non-condensing) | 20–95% RH (non-condensing) | 20–95% RH (non-condensing) |
| Noise | ≤50 dB | ≤50 dB | ≤50 dB |
BEFORE YOU CHOOSE
A few useful answers.
What is the second output for?
Connect essentials to the main output and less urgent loads to the controlled second output. Set when that second circuit switches off and reconnects as battery conditions change. Both circuits share the inverter’s total output capacity.
Can I control the second output by battery charge level?
Yes. All TH models support battery-voltage or SOC-based second-output control. For SOC control, connect a battery with a compatible BMS protocol and configure the communication settings.
Which TH models can run in parallel?
TH6248SMH and TH11048SMH support up to 12 matching inverters in parallel. TH4024SMH uses a 24 V battery system and operates as a standalone inverter.
Does every TH have two MPPT trackers?
TH4024SMH and TH6248SMH each have one MPPT tracker and 27 A PV input. TH11048SMH has two trackers, 27 A per input and up to 15 kW total PV input power.
Which output rating should I use for battery backup?
Use the battery-mode rating: 4, 6.2 or 11 kW. PV-mode output is listed separately as 4.5, 6.5 or 12 kW. The second output does not double the available power.